Standard Roof Pitch Michigan

This measurement is best done on a bare roof because curled up roofing shingles will impair your measurement.
Standard roof pitch michigan. Roof covering section maximum ultimate design wind speed v ult 140 mph maximum ultimate design wind speed v ult 140 mph. You can go by the measurements taken by walking the roof. Most roof s have a pitch in the 4 12 to 9 12 range. Table r905 1 1 2 underlayment application.
Since this is a flat roof or nearly flat roof. The pitch of a roof is its vertical rise over its horizontal span. The picture below shows the pitch of a 7 12 roof slope meaning that for 12 of horizontal measurement roof run the vertical measurement roof rise is 7. A pitch over 9 12 is considered a steep slope roof between 2 12 and 4 12 is considered a low slope roof and less than 2 12 is considered a flat roof.
I e 4 inches of rise per 12 inches one foot of run. For roof slopes from two units vertical in 12 units horizontal 2 12 up to four units vertical in 12 units horizontal 4 12 underlayment shall be two layers applied in the following manner. 0 pitch 1 00x the roof area. Although there is no single standard roof pitch used on all sloped roofs factors such as roofing materials and local climate help to determine the appropriate range of pitches for a given building.
The table below shows common roof pitches and the equivalent grade degrees and radians for each. If a roof slope rises say 4 inches when measured 12 inches along the bottom of a horizontal roof truss the roof slope is said to be 4 12. Rise multiplier rise multiplier 1 to 12 1 01 6 to 12 1 12 2 to 12 1 01 8 to 12 1 20 3 to 12 1 03 12 to 12 1 42 4 to 12 1 06 15 to 12 1 60 5 to 12 1 08 18 to 12 1 80. Roof slope multipliers for roof components of sloping roofs multiply by the figures given below to obtain the cost per square foot of horizontal projection.
Roof slopes are most commonly defined by the rise over run ratio. This is the slope of geometry stairways and other construction disciplines or the trigonometric arctangent function of its decimal. The minimum pitch for a roof is 1 4 12 which translates to 1 4 inch rise to 12 inches of run. Some of the most common roof pitch types are conventional slope type roofs designed with pitch ranging from 4 12 to 9 12.
However most often a ratio of pitch also fraction is slang used for the more useful slope of rise over run of just one side half the span of a dual pitched roof. Multipliers used for estimating roof area based on slope. Using roof pitch to order materials. These are utilized in residential applications.
Roof pitch is a measurement of a roof s slope expressed as a ratio.